If you are experiencing limited range with your Flex Prime's inbuilt Expression Pedal, it may be time to perform a re-calibration. This is easy to do and a great way to keep your Flex Prime in top shape before a show.
To re-calibrate your Flex Prime's inbuilt Expression Pedal, please do the following:
1. Hold the push encoder & footswitch 2 whilst powering on the Flex Prime.
2. FS 1 will light Green.
3. Move foot pedal to full toe-up position.
4. Press FS 1 to calibrate.
5. FS 1 will light orange then FS 2 will light up green.
6. Move foot pedal to full toe-down position.
7. Press FS 2 to calibrate.
8. FS 2 will light orange then FS 3 will light up green.
9. Move foot pedal to the middle position.
10. Press FS 3 to calibrate.
11. The unit will then load into normal operation.
Once the calibration process is complete, the Flex Prime should now accurately detect the inbuilt Expression Pedal's full range of movement, helping to ensure smooth and consistent control of assigned effects and parameters.