Numark NS7 & V7 | Calibration procedure
Print
Modified on: Thu, 29 Jun, 2023 at 10:10 AM
1. Disconnect the cable from the USB port and make sure the NS7 / V7 is off. While holding the right Deck's HOT CUE BUTTONS 1 and 3, turn the NS7's / V7's power on. HOT CUE BUTTONS 1-5 should flash twice.
2. Wait 10-20 seconds.
3. Set all faders and knobs to the maximum or right-most position. The PITCH FADERS should be at the bottom, which is their maximum.(See image below) The left Deck's HOT CUE BUTTON 1 will light up.
4. Press the lit left Deck's HOT CUE BUTTON 1. It will flash twice.
5. Set all faders and knobs to the minimum or left-most position. The PITCH FADERS should be at the top, which is their minimum.(See image below) The left Deck's HOT CUE BUTTON 1 will light up.
6. Press the lit left Deck's HOT CUE BUTTON 1. It will flash twice.
7. On the left Deck's STRIP SEARCH sensor:
Touch and hold the right-most position. When the left Deck's HOT CUE BUTTON 1 lights up, press it. It will flash twice.
Touch and hold the left-most position. When the left Deck's HOT CUE BUTTON 1 lights up, press it. It will flash twice.
Touch and hold the exact center position. When the left Deck's HOT CUE BUTTON 1 lights up, press it. It will flash twice.
8. Repeat Steps 8a-c with the right Deck's STRIP SEARCH sensor.
9. Set all faders and knobs to the middle/center position.(See image below) The left Deck's HOT CUE BUTTON 1 will light up.
10. Press the lit left Deck's HOT CUE BUTTON 1. The left Deck's HOT CUE BUTTONS 1-5 will flash, indicating that calibration is complete.
11. Turn the NS7's / V7's power off then on again before reconnecting it to your computer.